I’ve an MX960 field that confronted a problem as under.
Mater RE (RE1) cannot present any command invoke-on backup RE (RE0), for instance: present model invoke-on all-routing-engines.
{grasp}
nms@MX960> request routing-engine login other-routing-engine
join to deal with 128.0.0.4: Operation timed out
Attempting 10.0.0.4...
re0: Operation timed out
join to deal with 128.0.0.4: Operation timed out
Attempting 10.0.0.4...
re0: Operation timed out
####present database-replication abstract
{grasp}
nms@MX960> present database-replication abstract
Normal:
Sleek Restart Enabled
Mastership Grasp
**Connection Down**
Database Obtainable
Message Queue Not Prepared
####present activity replication
{grasp}
nms@MX960> present activity replication
Stateful Replication: Enabled
RE mode: Grasp
Protocol Synchronization Standing
OSPF NotStarted
BGP NotStarted
MPLS NotStarted
RSVP NotStarted
LDP NotStarted
I checked logs on backup RE (RE0) and acquired that interface ESW port 13 (interface connects SCB0 and RE0) flapped a number of occasions. However then, it’s up once more, however from RE1, I nonetheless could not present any command invoke-on backup RE (RE0).
From grasp RE, present chassis routing-engine, I see all REs (RE0 is backup an RE1 is grasp).
However from backup RE, present chassis routing-engine, state of grasp RE is Current.
**From RE0 (backup RE)**
viettel@KHA0011PRV01> present chassis routing-engine
Routing Engine standing:
Slot 0:
Present state Backup
Election precedence Grasp (default)
Temperature 31 levels C / 87 levels F
CPU temperature 30 levels C / 86 levels F
DRAM 16329 MB (16384 MB put in)
Reminiscence utilization 9 p.c
5 sec CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 0 p.c
Interrupt 0 p.c
Idle 100%
1 min CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 0 p.c
Interrupt 0 p.c
Idle 100%
5 min CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 0 p.c
Interrupt 0 p.c
Idle 100%
15 min CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 0 p.c
Interrupt 0 p.c
Idle 100%
Mannequin RE-S-1800x4
Serial ID 9009219924
Begin time 2022-08-18 11:39:45 ICT
Uptime 98 days, 22 hours, 4 minutes, 22 seconds
Final reboot motive Router rebooted after a traditional shutdown.
Load averages: 1 minute 5 minute 15 minute
0.02 0.11 0.14
Routing Engine standing:
Slot 1:
Present state Current
**From RE1 (grasp RE)**
{grasp}
nms@KHA0011PRV01> present chassis routing-engine
Nov 25 09:43:52
Routing Engine standing:
Slot 0:
Present state Backup
Election precedence Grasp (default)
Temperature 31 levels C / 87 levels F
CPU temperature 30 levels C / 86 levels F
DRAM 16329 MB (16384 MB put in)
Reminiscence utilization 9 p.c
5 sec CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 0 p.c
Interrupt 0 p.c
Idle 99 p.c
Mannequin RE-S-1800x4
Serial ID 9009219924
Begin time 2022-08-18 11:39:45 ICT
Uptime 98 days, 22 hours, 3 minutes, 17 seconds
Final reboot motive Router rebooted after a traditional shutdown.
Load averages: 1 minute 5 minute 15 minute
0.11 0.13 0.15
Routing Engine standing:
Slot 1:
Present state Grasp
Election precedence Backup (default)
Temperature 32 levels C / 89 levels F
CPU temperature 30 levels C / 86 levels F
DRAM 16329 MB (16384 MB put in)
Reminiscence utilization 9 p.c
5 sec CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 2 p.c
Interrupt 0 p.c
Idle 98 p.c
1 min CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 2 p.c
Interrupt 0 p.c
Idle 98 p.c
5 min CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 2 p.c
Interrupt 0 p.c
Idle 98 p.c
15 min CPU utilization:
Consumer 0 p.c
Background 0 p.c
Kernel 2 p.c
Interrupt 0 p.c
Idle 98 p.c
Mannequin RE-S-1800x4
Serial ID 9009219890
Begin time 2022-02-10 00:50:35 ICT
Uptime 288 days, 8 hours, 53 minutes, 13 seconds
Final reboot motive 0x1:energy cycle/failure
Load averages: 1 minute 5 minute 15 minute
0.14 0.23 0.23
After I rebooted RE0, every little thing OK.
Does anybody face the identical concern? Pls, give me some factors of your view.
Thanks.